Dynon Avionics D100 Series to SkyView Conversion Guide User Manual

Page 18

Advertising
background image

D10 and D100 Series Conversion To SkyView Guide – Rev D

Page 18

EFIS D25
Female
Connector
Pin No.

EFIS D25
Connector
Wire
Color

EFIS Function

Notes for conversion to SkyView SV-HARNESS-D37

21

WHITE

SERIAL 2 GROUND

If this wire was used for connection to transponder (or
Dynon 100362-000 Serial-to-Gray Code Encoder
Converter Module), reroute this wire to SkyView
Display Master Ground, common with SV-HARNESS-
D37 black wires on Pins 21 & 22

22

YELLOW

SERIAL 1 - RX

If this wire was used for connection to PC, no longer
required; remove this wire.
If this wire was used for connection to GPS or NAV
radio, reroute this wire to SkyView Display Serial Port
RX.

23

WHITE /
GREEN

EDC-D10A DATA A

Not used in SkyView system.
Remove this wire.

24

WHITE

EDC-D10A GND

Not used in SkyView system.
Remove this wire.

25

This pin is not used, and thus not populated in the EFIS Connector – no wire.