EMS D37
Female
Connector
Pin No.

EMS D37
Connector Wire
Color

EMS Function

SV-EMS-220
Function

Sensor / Wiring Conversion To
SV-EMS-220

26

GREEN/RED

MANIFOLD
PRESSURE

MANIFOLD
PRESSURE

No changes required.

27

(NO WIRE)

GENERAL
PURPOSE
THERMOCOUPLE
+ (J OR K)

GENERAL
PURPOSE
THERMOCOUPLE
1 + (J OR K)

No changes required.

28

(NO WIRE)

GENERAL
PURPOSE
THERMOCOUPLE
- (J OR K)

GENERAL
PURPOSE
THERMOCOUPLE
1 + (J OR K)

No changes required.

29

YELLOW/GREEN

EMS ALARM
LIGHT OUTPUT

EMS ALARM
LIGHT OUTPUT

No changes required.

30

BLACK

PC SERIAL
GROUND

GROUND

New capability - now a sensor
ground. Cut off the 9-pin
connector to use this wire.
If connected to PC (firmware,
data logs), no longer required.

31

WHITE/ORANGE

AUDIO OUTPUT

GENERAL
PURPOSE INPUT
13 (TYPE C)

New capability – now a General
Purpose input.
If connected to audio output,
reroute this wire to SkyView
display. Because EFIS Audio
was mono, connect this wire to
both SkyView Display
PIN 13 – AUDIO OUTPUT LEFT
and
PIN 31 – AUDIO OUTPUT RIGHT
If a 10K potentiometer was
installed on this to adjust
volume, remove it (SkyView has
internal volume adjustment).

32

WHITE/GREEN

RPM LEFT

STANDARD
VOLTAGE RPM
LEFT

If connected to Rotax engine
(5

th

trigger coil), remove 30K

resistor.

If not connected to Rotax, no
changes required.