Guidelines for Conversion of Accessories

The Dynon Heated AOA Pitot Probe Controller includes an output that is used to indicate failure
of the heating system. Because of limited inputs on a Dynon Avionics EMS, this circuit was often
wired to a separate indicator light. Because SkyView SV-EMS-220 has more available inputs, it is
common to connect the “Heater Failure” output to the SV-EMS-220 which can then display the
status of the “Heater Failure” (red, or green) on the SkyView EMS page. See the section
regarding Contacts in the SkyView System Installation Guide.

If your plane has serial port connectors built-in to the panel (for firmware updates), those will
no longer be used in conjunction with SkyView (except for the rare case of streaming data).
Consider replacing panel-mounted serial connectors with panel-mounted female USB
connectors for easy updating of your SkyView displays.