Guidelines for Conversion of Dynon Avionics EMS CHT/EGT Harness to
SkyView SV-EMS-220 CHT/EGT Harness

The CHT/EGT 25-pin connector is “Plug and Play”. If the CHTs and EGTs were installed and
working on the Dynon Avionics EMS and no changes are needed, there is no wiring conversion
required to work with an SV-EMS-220. The CHT/EGT 25-pin female connector on the SV-EMS-
220 is electrically compatible with the CHT/EGT 25-pin female connector on a Dynon Avionics
EMS.

For a detailed explanation of the full (enhanced) range of capabilities for each pin of the SV-
EMS-220 CHT/EGT 25-pin connector, see these tables and figures in the SkyView System
Installation Guide, SV-EMS-220 Installation and Configuration:

SV-EMS-220 Female D25 Pin-to-Sensor Compatibility

Thermocouple Wire Harness Male D25 Pin Insertion View (Rear)