D10 and D100 Series Conversion To SkyView Guide – Rev D

Page 21

EMS D37
Female
Connector
Pin No.

EMS D37
Connector Wire
Color

EMS Function

SV-EMS-220
Function

Sensor / Wiring Conversion To
SV-EMS-220

4

VIOLET/BLUE

GENERAL
PURPOSE INPUT
1

GENERAL
PURPOSE INPUT
1 (TYPE A)

If connected to Dynon P/N
100413-000 Carb Temp Sensor,
remove the 1K resistor installed
between this pin and Pin 18
(+5V Output).

If connected to Dynon 100411-
000 Pressure Sensor for
monitoring coolant
, remove the
1K resistor installed between
this pin and Pin 18 (+5V
Output).

If connected to Dynon 100409-
000 or 100409-001 Oil /
Coolant Temp Sensor for
monitoring coolant
, remove the
1K resistor installed between
this pin and Pin 18 (+5V
Output).

If connected to Rotax CHT,
remove the 1.21K resistor
between this pin and Pin 18
(+5V Output).

If connected to Dynon 100433-
000 OAT, see Guidelines For
Connection of Installed OAT to
SV-ADAHRS-200/201 OAT
Input.

5

BLACK

GROUND

SIGNAL
GROUND

No changes required.

6

WHITE/YELLOW

OIL PRESSURE

GENERAL
PURPOSE INPUT
11 (TYPE B)

No changes required.

7

WHITE/BROWN

OIL
TEMPERATURE

GENERAL
PURPOSE INPUT
12 (TYPE A)

No changes required.

8

BROWN

FUEL PRESSURE

GENERAL
PURPOSE INPUT
4 (TYPE C)

If connected to Rotax P/N
956413 (Honeywell) or Rotax
P/N 456180, remove 200 ohm
resistor between Pin 8 and
ground.