After updating 6416y2 firmware – Aviom Pro64 Network Manager User Manual

Page 36

Advertising
background image

27

P

ro

64 N

etwork

M

aNager

U

ser

g

Uide

After Updating 6416Y2 Firmware

Once new firmware is installed, DIP switch #9, found in DIP Switch Block 9 (SW9), is used to select between

Pro64 Network Manager enabled (when up, the software controls all I/O routing and settings) or DIP

switch control (when down, the card’s onboard DIP switches control the I/O routing and settings on the

6416Y2 card). This switch needs to be in the down position for the initial firmware update from v2.xx, v3.xx,

or v4.xx to version 5.xx.

Move DIP switch #9 to

the up position after

updating the card’s

firmware.

Move DIP switch #1 to the up

position after updating the

card’s firmware for RS-422

control.

Leave DIP switch #10

up after updating the

firmware if the card

will be Control Master.
Move it to the down

position if the card

is a slave or used for

m-control.

ON

ON

ON

ON

ON

ON

SW7

SW8

SW3

SW9

SW4

SW1

SW2

1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8 9 10

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

6416Y2 card is ready for control and management from Pro64 Network Manager after being updated.

Leave the Managed Mode DIP switch (#10 in block SW9) in the up position on a card set to be the network’s

Control Master. Move this switch to the down position if the card will be a slave. Remember that only one

Pro64 device or 6416Y2 card can be the network’s Control Master, so only one card can have its DIP switch

#10 in block SW9 set to the up position.

If a 6416Y2 card is used as Control Master, it is not possible for that same card to send m‑control information.

The options are: (1) use a different 6416Y2 card for m‑control or (2) use a different Pro64 device as the

network’s Control Master. Switch Block SW4, the baud rate settings, can be left set as shown to simplify

future firmware updates. Additional information about the 6416Y2 card starts on page 83.

P

N

ote

:

Once the 6416Y2 card’s firmware has been updated, DIP switch #9 in DIP Switch Block 9 (SW9)

needs to be placed in the up position to enable control from Pro64 Network Manager. Power

down the Pro64 network and the host Yamaha devices and set all 6416Y2 cards in this manner;

restart the Yamaha devices and the Pro64 network to continue.

Advertising