Standby From a Contact Closure

Standby Mode can also be activated by wiring a contact closure switch to the Standby Euroblock connector

on the top panel of the F6 hardware. This allows a physical switch to trigger the standby state as might

required if the AllFrame was built into an electrical enclosure with a door that was to be closed when the

device was not in use. To differentiate this type of Standby behavior from that initiated by software or the

momentary switch it is referred to as Hardware Standby.

An AllFrame in hardware standby

When an AllFrame is placed into Standby Mode using a physical contact closure device, it will display a

special lock icon in the Device Window that reads

h

ArDwAre

s

tANDBY

A

ctIve

in red along with the yellow

warning triangle. (Notice that the Standby Mode’s radio button remains set to

o

FF

in this case.) Pro64

Network Manager cannot change this standby state. The contact closure must be opened manually to

return the AllFrame to normal operation.