HI 1746-WS WEIGH SCALE MODULE

4-14

Error Return Values:

STATUSWORD - there was a conversion error,
weight in motion or an A/D error or all three.

C2FAILNODEVS - did not detect any C2 load
cells.

C2FAILCAPEQ - detected two load cells with
different capacities.

SEQ

NUMBER

0

COMMAND#

(Hex)

1

STATUS

2

OFFSET

3

LENGTH

4

DATA

5-16

From M1 File

0x66

Read C2 Serial
Number Command
(READC2SERIALN
UM)

The Read C2 Serial Number Command - Reads the 9
byte serial number from a C2 chip located on every
C2 load cell. Specify the index of the C2 chip to read
in commandData.offset of the Mfile. The index
should be a number of 0 to C2RomX-1 (-1 is a minus
one not a dash one), where C2RomX is the number of
C2 chips. The “serial number” will be 8 bytes of
ASCII text, followed by a 0 terminator.

Error Return Values:

OUTOFTOLERANCE - specified chip is not
found.

SEQ

NUMBER

0

COMMAND#

(Hex)

1

STATUS

2

OFFSET

3

LENGTH

4

DATA

5-16

From M1 File

0x70

Set Parameters
Command
(SETPARAM)

Sets a parameter in the module. (See Setting the Pro-
cess Weighing Parameters below for more detailed
information.)