FLUKE 900 SERVICE MANUAL

Maintenance

probe B to the output of a related ’86 gate and measure t3 and t4.
- Press any key to abort the looping activity. Press lS)(l_fault) and measure t5, t6, t7,

t8 as indicated on figure 3b. Pressing any key aborts the looping activity.

A:

■A

B(HF)

B(LF)

CCLF)

fig. 3

q

fig. 3b

Calculate the following values:

A= abs(tl-t5)
B = abs(t2-t6)

If A>B then 74AS244 generates too big an offset and should be replaced.
If A<B then 74AHCT86 is faulty and should be replaced.
If A=B then calculate new values:

A = abs(t3-t7)
B = abs(t4-t8)

Now, if A>B then 74AS244 generates too big an offset and should be replaced.
If A<B then 74AHCT86 is faulty and should be replaced.
If A=B any of them may be replaced.
The calibration procedure should then be restarted.

5 - 1 5