Chapter 5. Installation and Testing

Rebuilding RedBoot

These shell variables provide the platform-specific information needed for building RedBoot according to the
procedure described in

Chapter 3

:

export TARGET=hs7729pci

export ARCH_DIR=sh

export PLATFORM_DIR=hs7729pci

The names of configuration files are listed above with the description of the associated modes.

SuperH/SH3(SH77X9) Hitachi Solution Engine 77X9

Overview

This

description

covers

the

MS7729SE01

and

MS7709SSE0101

variants.

See

the

Section

called

SuperH/SH3(SH7709) Hitachi Solution Engine 7709

for instructions for the MS7709SE01 variant.

RedBoot uses the COM1 and COM2 serial ports. The default serial port settings are 38400,8,N,1. Ethernet is also
supported using the 10-base T connector. Management of onboard flash is also supported.

The following RedBoot configurations are supported:

Configuration

Mode

Description

File

ROM

[ROM]

RedBoot running from the
board’s flash boot sector.

redboot_ROM.ecm

RAM

[RAM]

RedBoot running from
RAM with RedBoot in the
flash boot sector.

redboot_RAM.ecm

Initial Installation Method

The Solution Engine ships with the Hitachi boot monitor in EPROM which allows for initial programming of
RedBoot:

1. Set switches SW4-3 and SW4-4 to ON [boot from EPROM]

2. Connect a serial cable to COM2 and power up the board.

3. After the boot monitor banner, invoke the flash download/program command:

Ready

>

fl

163