Configuration Using the Web Interface

Warning

The ES7528 provides several types of warning features for you to remotely monitor the status of the attached
devices or changes in your network. The features include Fault Relay, System Log, and SMTP Email Alert.

The following web pages are included in this group:

Fault Relay

Event Selection

on Page 125

SysLog Configuration

on Page 126

SMTP Configuration

on Page 127

Optionally, you can use the CLI for configuration, see

Warnings (CLI)

on Page 192.

Fault Relay

The ES7528 provides one digital output (Relay Output). The
relay contacts are energized (open) for normal operation and
close under fault conditions: Fault conditions include Power
Failure, Ethernet port Link Failure, Ping Failure, and Super
Ring Topology changes. Each Relay can be assigned 1 fault
condition.

Relay 1: Click the Relay 1 check box and then select the Event
Type and its parameters.

Event Types: Dry Output, Power Failure, Link Failure, Ping
Failure, and Super Ring Failure. Each event type has its own
parameters. You can configure each Event Type. Each Relay
has one event type.

Event Type: Dry Output

On Period (Sec): Type the period time to turn on Relay
Output. The available time period range is 0 - 4294967295 seconds.

Off Period (Sec): Type the period time to turn off Relay Output. The available time period range is 0 -
4294967295 seconds.

How to Configure: Enter turn-on and turn-off periods, when the time is reached, the system turns on or
turns off the Relay Output.

Relay turned on for 5 seconds then
off for 10 seconds
.