Warnings (CLI) - 193

Configuration Using the Command Line Interface (CLI)

Event Selection

Event Selection

Switch(config)# warning-event

coldstart Switch cold start event

warmstart Switch warm start event

linkdown Switch link down event

linkup Switch link up event

authentication Authentication failure event

fault-relay Switch fault relay event

poe-powering Switch PoE powering or unpowered event

power Switch power failure event

sfp-ddm Switch SFP DDM abnormal event

super-ring Switch super ring topology change event

time-sync Switch time synchronize event

Example:

Cold Start event

Switch(config)# warning-event coldstart

Set cold start event enable ok.

Example:

Link Up event

Switch(config)# warning-event linkup

[IFNAME] Interface list, ex: fa1,fa3-5,gi25-28

Switch(config)# warning-event linkup fa1gi2

Set fa5 link up event enable ok.

Display

Switch# show warning-event

Warning Event:

Cold Start: Enabled

Warm Start: Disabled

Authentication Failure: Disabled

Link Down: fa4-5

Link Up: fa4-5

Power Failure:

Super Ring Topology Change: Disabled

Fault Relay: Disabled

Time synchronize Failure: Disabled

PoE Powering:

SFP DDM: Enabled