76 - PoE Control

RocketLinx ES7528 User Guide: 2000509 Rev. C

Configuration Using the Web Interface

The following illustrates how to configure IEEE 802.3at LLDP. Assume the PD is ready for the configuration
for IEEE 802.3at LLDP, you only need to confirm the ES7528 configuration.

For example, connect the port of the ES7528 to the PD (Port 4), set PoE Mode is Enable and Powering Mode is
802.3at(LLDP). When the ES7528 and the PD are ready to IEEE 802.3at LLDP, IEEE 802.3at LLDP starts
operation. Refer to

PoE Status

on Page 78, to see the PoE Status page.

PoE Control

PoE System

You can Enable/Disable ports, or set it to scheduling control mode.

DC1/DC2

Power Budget
(W)

The output power range is 1-480W.

Port Configuration

PoE Mode

You can select Disable, Enable, or Schedule for PoE mode for each port. Select Schedule to
enable the port in the PoE Schedule page (

Page 77

).

Powering
Mode

Use this mode to change the Powering Mode to one of the following:

802.3af If the PD follows IEEE 802.3af, then the ES7528 delivers
power.

802.3at(LLDP) Delivers power to a PD that supports IEEE 802.3at
LLDP.

802.3at(2-Event) Delivers power to a PD that supports 2-Event.

Force If Force is enabled, the port directly delivers the power even if
there is no Ethernet cable connected.

Note: Use caution when using Force mode. Do not connect a standard Ethernet device if

using Force mode, it will damage the device.

Power Priority

Power Priority lets the PoE port with higher priority to deploy power under the limit power
budget. There are three priorities (Critical, High and Low).

PD Status Detection

PD Status
Detection

Enable/Disable the PD Status Detection function.

IP Address

Type in the IP address that you want to detect.

Cycle Time(s)

This is the gap per detection in seconds. The range is 10-3600 seconds in multiples of 10.

Apply

Click Apply to apply the settings.

Note: You must Save the settings (