Comtrol ES7528 User Manual

Page 164

Advertising
background image

164 - Power over Ethernet (CLI)

RocketLinx ES7528 User Guide: 2000509 Rev. C

Configuration Using the Command Line Interface (CLI)

PoE Budget Warning (%)

Set

Switch> enable

Switch# config term

Switch(config)# interface fa1

Switch(config-if)# poe budget warning

<0-100> 0 is disable, valid range is 1 to 100 percentage

Switch(config-if)# poe budget warning 60

PoE Priority

Set

Switch> enable

Switch# config term

Switch(config)# interface fa1

Switch(config-if)# poe priority

critical Hightest priority level

high High priority level

low Low priority level

Switch(config-if)# poe priority critical

PoE Schedule Weekday Hour

Enable Hour 1, 3, 5
and 10 to 23 on
Sunday

Switch> enable

Switch# config term

Switch(config)# interface fa1

Switch(config-if)# poe schedule

<0-6> Weekday: valid range 0-6 (0=Sun, 1=Mon..., 6=Sat)

Switch(config-if)# poe schedule 0 1,3,5,10-23

Disable Sunday
Schedule

Switch(config-if)# no poe schedule 0

PoE Budget DC1/DC2

Set

Switch(config)# poe

disable Disables power over ethernet

enable Enables power over ethernet

budget Configure the power budget of power over ethernet

pd-detect Configure PD status detection

Switch(config)# poe budget

DC1 Power source : DC 1

DC2 Power source : DC 2

vin Input voltage

warning Warning water level

Switch(config)# poe budget DC1

[POWER] System budget : 1 - 400 Watts

Switch(config)# poe budget DC1

DC1 Power source : DC 1

DC2 Power source : DC 2

vin Input voltage

warning Warning water level

Switch(config)# poe budget DC1 400

Advertising