Cisco XR 12406 Router Installation Guide

OL-13831-01

Chapter 1 Cisco XR 12406 Router Overview

Line Cards

Power Distribution

The router chassis backplane distributes -48 VDC power throughout the router
and to all cards in the card cages.

All cards have multiple DC-DC converters that convert the -48 VDC into
+2.5 VDC, +3.3 VDC, +5 VDC, and other voltages as required by the line card.
The DC-DC converters are turned on by the MBus modules under the control of
the route processor and MBus software.

Power for the blower module is supplied directly from the backplane through a
connector in the PDU that passes DC voltage from the backplane to the blower
module. An blower module controller card in the blower module converts
–48 VDC into DC voltage that powers the blower module fans.

Caution

To ensure that the chassis configuration complies with the required power
budgets, use the on-line power calculator. Failure to properly verify the
configuration may result in an unpredictable state if one of the power units fails.
Contact your local sales representative for assistance.

Blower Module

The Cisco XR 12406 Router is equipped with a blower module to distribute air
within the chassis. The blower module is located on the rear of the chassis (see

Figure 1-3

). The blower module draws room air into the chassis through two air

filters on the side of the chassis, pulls the air through the chassis card cages, and
expels it through exhaust vents on the back of the blower module (

Figure 1-17

).

Caution

Exhaust from other equipment vented directly into the router air inlet may cause
overheating. The front, back, and sides of the router must remain unobstructed to
ensure adequate air flow and prevent overheating inside the chassis. Allow
sufficient air flow by maintaining 6 inches (15.24 cm) of clearance at both the
inlet and exhaust openings on the chassis.