Chapter 3 Installing the Cisco XR 12406 Router

Manually Booting the System

3-38

Cisco XR 12406 Router Installation Guide

OL-13831-01

RP Alphanumeric LED

RP alphanumeric LEDs are located at one end of the RP faceplate, near the ejector
lever.

Figure 3-22

shows the RP LED displays.

Figure 3-22

RP Alphanumeric LED Displays

Each 4-digit display shows part of a 2-line system message. During the RP boot
process, the LED displays present a sequence of messages similar to that shown
in

Table 3-7

.

Right alphanumeric
LED display (four digits)

Left alphanumeric

LED display (four digits)

57079

Table 3-7

LED Display Meaning and Signal Source

LED
Display

Meaning

Source

MROM

nnnn

The MBus microcode begins to execute; nnnn is the
microcode version number. For example, microcode
version 1.17 displays as 0117.

1

Note

This display might not be visible because it occurs for only

a brief time.

MBus
controller

LMEM

TEST

Low memory on the RP is being tested.

RP ROM
monitor

MEM

INIT

The size of main memory on the RP is being discovered. RP ROM

monitor

RP

RDY

The system is operational and ready to execute basic
Cisco IOS XR software commands at the ROM monitor
prompt (

rommon>

).

RP ROM
monitor