Table 3-6 – Cisco XR 12406 User Manual

Page 115

Advertising
background image

3-27

Cisco XR 12406 Router Installation Guide

OL-13831-01

Chapter 3 Installing the Cisco XR 12406 Router

Connecting to an AC Power Source

Refer to

Figure 3-18

and use the following procedure to connect AC power to the

AC PDU.

Note

When operating your router on a single power module, the second power module
bay must have a blank filler (MAS-GSR-PWRBLANK=) installed to ensure EMI
compliance.

Step 1

Attach an ESD-preventive strap to your wrist and connect the leash to the chassis
or to another grounded, bare metal surface.

Step 2

Locate the two AC power cords and remove them from their shipping packaging.
Verify that the AC power cords shipped with the power supplies are the correct
type for your site.

Note

If you have received the wrong type of AC power cord, contact your
service representative for a replacement.

Table 3-6

Required Power Combinations

Router Power

Combination

AC power

1 AC-input power supply

1 power supply blank

2 AC-input power supplies

DC power

1 DC-input PEM

1 PEM blank

2 DC-input PEMs

Advertising