Switch fabric redundancy, Alarm cards – Cisco XR 12406 User Manual

Page 41

Advertising
background image

1-25

Cisco XR 12406 Router Installation Guide

OL-13831-01

Chapter 1 Cisco XR 12406 Router Overview

Line Cards

Switch Fabric Redundancy

Equipping the router with two CSCs provides data path, scheduler, and reference
clock redundancy. The interfaces between the line cards and the switch fabric are
monitored constantly. If the router detects a loss of synchronization (LOS), it
automatically activates the data paths of the redundant CSC, and data flows across
the redundant path. The switch to the redundant CSC occurs within 0.5 second,
with little or no loss of data.

Note

The enhanced Cisco XR 12406 chassis (XR-12000/6 configured with 12406/120
fabric option) ships with redundant CSC which is required to maintain High
Availability for the system.

Alarm Cards

The Cisco XR 12406 Router has two alarm card slots (

Figure 1-12

). Each alarm

card performs the following function or indicates the following condition:

Alarm output

CSC status

SFC status

Alarm card status

Power source and power entry module status

Alarm relay contacts

The entire alarm function has been implemented on redundant alarm cards with
OIR maintenance (hot-swappable) functionality.