Alarm output function, Alarm – Cisco XR 12406 User Manual

Page 42

Advertising
background image

Chapter 1 Cisco XR 12406 Router Overview

Line Cards

1-26

Cisco XR 12406 Router Installation Guide

OL-13831-01

Figure 1-12

Alarm Card Features

Note

The Cisco XR 12406 Router must be populated with two alarm cards, to meet
EMI standards.

Alarm Output Function

The alarm output function consists of a group of relays, LEDs, and their
associated drivers connected to an output port on the MBus module.

The alarm output function is controlled by the software on the route processor.
When a signal is received from the route processor, the MBus module on the alarm
card activates specific relays to signal an alarm condition. There are three alarm
condition severity levels: critical, major, and minor. The critical, major, and minor
LEDs are paired for redundancy to protect against a single failed LED.

Note

Alarm cards for some Cisco XR 12000 Series Router have both audible and
visible alarm indicators. The alarm card for the Cisco XR 12406 Router provides
only visible alarm indicators as local alerts to unusual conditions in the router.

1

MBus status LED

5

Major alarm LED

2

CSC status LEDs (two)

6

Minor alarm LED

3

SFC status LEDs (three)

Alarm relay contact connector

4

Critical alarm LED

MB

US

CSC

ENABLED

FAIL

ALARM

0

SFC

CRITICALMAJOR MINOR

0

1

1

2

1

4

3

2

5

6

66170