Table a-7, Immunity tests – Cisco XR 12406 User Manual

Page 229

Advertising
background image

A-7

Cisco XR 12406 Router Installation Guide

OL-13831-01

Appendix A Cisco XR 12406 Router Technical Specifications and Warnings

Compliance Information

Table A-7

Immunity Tests

Test Type or Specification

Applies to

Class/Level/Criteria

Electrostatic Discharge

EN61000-4-2:1995

System/enclosure

Level 4/8KV contact, 15KV air/B

Radiated Immunity

IEC61000-4-3:1995

ENV50140:1993

System/enclosure

Level 3/10V/m/A

1KHz 80% AM

(80MHz - 1 GHz)

Fast Transients

EN61000-4-4:1995

AC power lines


DC lines


Signal lines

Level 4/4 KV 2.5 kHz Rep Freq/B


Level 4/4 KV 2.5 kHz Rep Freq/B


Level 4/1 KV 5kHz Rep Freq/A

Level 4/2 KV 5kHz Rep Freq/B

Surge Immunity

EN61000-4-5:1995

AC power line (live-neutral)

2 ohms


AC power line (live-earth)

12 ohms


DC power line (live-earth)


DC Power line (return-earth)


Signal lines 2 ohms

Class 4/2KV/B


Class 4/4KV/B


Class 4/500V/B


Class 4/500V/B


Indoor: 500V

Outdoor: 4KV/R

Conducted RF Immunity

EN61000-4-6:1996+

ENV50141:1993

AC power line

DC power line

Signal lines

Level 3/10V/A

(150kHz-80MHz)

Voltage Dips + Sag

Interruptions

AC Power Lines

EN61000-4-11:1995

AC power lines

30% 10 ms (0.5 period)/B

30% 5000ms (25 periods)

60% 100 ms (5 periods)/C

60% 1000 ms (50 periods)

>95% 10ms (0.5 period)/C

>95% 5000 ms (250 periods)

Advertising