MODELS

GB920

GB940

GB960

Performance characteristics

Batch size lbs {g}

19.8 {9000}

19.8 {9000}

19.8 {9000}

Maximum throughput lbs/hr

{kg/hr}*

5200 {2359}

3300 {1497}

2124 {965}

Bin capacity - main ingredient

ft

3

{liter}

8.5 {240.7}

6.7 {189.7}

3.6 {102.9}

Bin capacity - minor ingredient

ft

3

{liter}

NA

3.6 {107.6}

3.6 {107.6}

Maximum number of materials

6

8

10

Number of discharge valves

2

4

6

Number of additive feeders

up to 4

up to 4

up to 4

Control software (# of components)

4 or 12

4 or 12

12

Dimensions inches {mm}

A - Height above mounting plate

74 {1880.7}

74 {1880.7}

74 {1880.7}

B - Width

56 {1421.4}

56 {1421.4}

56 {1421.4}

C - Depth

34 {863.6}

34 {863.6}

34 {863.6}

D - Controller height

11.25 {285.75}

11.25 {285.75}

11.25 {285.75}

E - Controller width

12.25 {311.15}

12.25 {311.15}

12.25 {311.15}

F - Controller depth

8.19 {208.03}

8.19 {208.03}

8.19 {208.03}

Weight lbs {kg}

Installed

480 {218}

480 {218}

480 {218}

Shipping

600 {272.2}

600 {272.2}

600 {272.2}

Voltage Running load amps

§

120V/1 phase/60 hz (control and mixer)

8.5

8.5

8.5

220V/1 phase/60 hz (control and mixer)

4.25

4.25

4.25

220V/1 phase/50 hz (control)

0.15

0.15

0.15

220V/3 phase/50 hz (mixer)

2.2

2.2

2.2

400V/3 phase/50 hz (mixer)

1.1

1.1

1.1

Compressed air requirements

Discharge valves

80 psi @ 0.2 ft

3

/min {5.5 bars @ 0.09 liters/sec}; 1/4 in. NPT fitting

Compressed air feeder

40 psi @ 2.0 ft

3

/min {2.8 bars @ 0.94 liters/sec}; 1/4 in. NPT fitting

Maximum loader sizes **

Number of 20 inch loaders

2

2

3

Number of 15 inch loaders

2

4

6

GRAVIMETRIC BATCH BLENDERS

AutoWeigh GB900 Series Models

MOUNTING INTERFACE

SPECIFICATION NOTES:

* Maximum throughput rates are based on 35 lbft

3

pelletized material and using all dispense valves.
Use of feeders for minor ingredients will reduce
this rate. Refer to the selection guide for more
specific throughput information.

† The optional flow control valve will add 6.5 in. {165

mm} to the total height. We recommend using the
flow control valve when mounting the blender to a
stand, surge bin or hopper.

‡ Feeders will increase depth dimensions. Please

refer to feeder specification.

§ Each auger feeder requires an additional 1 amp @

120V or 0.5 amp @ 240V.

** Maximum loader sizes may be used only when the

loader is adjacent to loaders of a smaller diameter.

SPECIFICATIONS

TPBS013/1199

IBO4

CONTROL

FEEDER LOCATIONS

2

1

D

C

B

A

B

C

GB920

2

1

D

C

B

A

B

C

GB940

A

B

C

GB960

4

3

8

1

7

2

4

3

A

B

C

FRONT VIEW

GB920

SIDE VIEW

GB920/GB940

A

B

C

FRONT VIEW

GB940/GB960

SIDE VIEW

GB960

B

C

D

NOTE: Any one of the
feeders (A,B,C or D)can be
designated position 5 or 6.

APPENDIX B