Specifications, Appendix b – Conair GB User Manual

Page 111

Advertising
background image

One Conair Drive

Pittsburgh, PA 15202

412-312-6000

FAX 412-312-6227

www.conairnet.com

MODELS

WSB1840

WSB1850

WSB1860

Performance characteristics

Batch size lbs {g}

39.7 {18000}

39.7 {18000}

39.7 {18000}

Maximum throughput lbs/hr {kg/hr}*

4114 {1866}

3160 {1433}

2566 {1164}

Bin Capacity - Main Ingredient ft

3

{liter}

6.7 {189.7}

6.7 {189.7}

3.8 {107.6}

Bin Capacity - Minor Capacity ft

3

{liter}

3.8 {107.6}

3.8 {107.6}

3.8 {107.6}

Maximum number of materials

8

9

10

Number of discharge valves

4

5

6

Number of additive feeders

up to 4

up to 4

up to 4

Control Software (# of components)

4 or 12

12

12

Dimensions inches {mm}

A - Height above mounting plate

93 {2362.2}

93 {2362.2}

93 {2362.2}

B - Width†

56.25 {1428.8}

56.25 {1428.8}

56.25 {1428.8}

C - Depth†

34.4 {873.8}

34.4 {873.8}

34.4 {873.8}

D - Controller height

11.25 {285.75}

11.25 {285.75}

11.25 {285.75}

E - Controller width

12.25 {311.15}

12.25 {311.15}

12.25 {311.15}

F - Controller depth

8.19 {208.03}

8.19 {208.03}

8.19 {208.03}

Weight lbs {kg}

Installed

730 {331}

730 {331}

730 {331}

Shipping

850 {385.5}

850 {385.5}

850 {385.5}

Voltage Running load amps‡

110V/1 phase/60hz (control)

0.3

0.3

0.3

220V/1 phase/60hz (mixer)

8.2

8.2

8.2

220V/1 phase/60hz (control)

0.2

0.2

0.2

220V/1 phase/60hz (mixer)

8.2

8.2

8.2

220V/1 phase/50hz (control)

0.2

0.2

0.2

220V/3 phase/50hz (mixer)

4.4

4.4

4.4

400V/3 phase/50hz (mixer)

2.2

2.2

2.2

Compressed air requirements

Discharge valves

80 psi @ 0.2 ft

3

/min {5.5 bars @ 0.09 liters/sec}

1/4 in. NPT fitting

Maximum loader sizes §
Number of 20 inch loaders

2

2

3

Number of 15 inch loaders

4

5

6

GRAVIMETRIC BATCH BLENDERS

WSB 1840, 1850 and 1860 Models

MOUNTING INTERFACE

SPECIFICATION NOTES:

* Maximum throughput rates are based

on using all dispense valves and 35
lb/ft

3

pelletized material. Use of feed-

ers will reduce this rate.

† Feeders will increase width and depth

dimensions. Please refer to feeder
specifications.

‡ Each auger feeder requires an addi-

tional 1 amp @ 120V or 0.5 amp @
240V.

§ Maximum loader sizes may be used

only when the loader is adjacent to
loaders of a smaller diameter.

(4) 9/16 in. {14.3 mm}

diameter bolt holes

4 in. {101.6 mm}

diameter

through hole

8 in. {203.2 mm}

square bolt pattern

15 in. {381 mm}

14.5 in.

{368.3 mm}

16 in.
{406.4 mm}

20 in. {508 mm}

SPECIFICATIONS

TPBS005/0700

IB04

0

0

0

0

0

0

0

0

0

A

C

C

B

CONTROL

Note: loader
configuration
same for all
models

APPENDIX B

Advertising