INSTRUCTIONS FOR NORMAL OPERATION

OPERATION: ....very simple.

1. Fill HOPPERS.

2. Turn POWER ON. Verify correct settings.

3. On Controller, set STOP and PAUSE switches UP.
Turn MIXER motor switch DOWN to run for a timed period.

Unit will now operate automatically to maintain a level of material
high enough to cover the sensor.

Use the STOP or PAUSE switches to stop the blender.
Turn POWER off only on final shutdown.
----------------------------------------------------------------------

AFTER SEVERAL DAYS OF PROPER OPERATION:

Save all parameter information to the EEPROM for future retrieval just
in case software problems develop later.

To SAVE all parameter information to the EEPROM:

+---------------------------------------------------+
¦ Press: * Display will say: (PASSWORD) ¦
¦ Press: 22222 Display will say: (P x) ¦
¦ Press: * Display will say: (INSTR --) ¦

¦ Press: 23 Display will say: (SAVING ) ¦
¦ Wait: when done, Display will say: (P x) ¦
¦ Press: EXIT Display will say: ( x) ¦
+---------------------------------------------------+

If software related problems develop later, RETRIEVE this correct copy
of the parameters from the EEPROM. This clears corrupted data from RAM
and corrects most software problems.

To Retrieve:
+----------------------------------------+
¦ Switch: POWER OFF. ¦
¦ Hold: the "CE" key down. ¦
¦ Switch: POWER ON. ¦
¦ Release: the "CE" key. ¦
¦ Display will say ( CLEAR ) ¦
¦ If you do not see ( CLEAR ) ¦
¦ on the display, do it again. ¦

+----------------------------------------+