Conair GB User Manual

Page 65

Advertising
background image

such as regrind, but you wish the process to continue even
without the component.

00021 to 00029 = same as 1 to 9, Stop Process, Sound Alarm, but NO more

retries. Just sound alarm and wait. Press the RESET button to
clear alarm and start the retries again. Appropriate ONLY if you
absolutely want operator intervention to occur when material runs
low. In other words you do not want any automatic loading or
other correction to allow the process to continue.

The first three digits of this parameter (_AL xxx00) may be used
to STOP and ALARM the blender if an over dispense occurs by the number
of grams specified. For example, CAL 02004 will cause the system to
STOP and ALARM if the COLOR dispense is 20 grams over target.

(C - OVER) will be displayed. Use PAUSE (or POWER OFF) to reset the
Alarm condition. If a printer is connected, a standard cycle printout
will occur.
======================================================================

_XT (Allows a setting entry of less then 00.1)

_XT, is a number that will alter the value of the setting that you
enter. The value of the XT parameter, is divided into the setting,

thereby reducing the setting's value. The only valid entries are 10
and 100. When set to "00010" the decimal point is moved to the left
one place and the setting is read as X.XX percent. When set to "00100"
the decimal point is moved to the left two places and the setting is
read as .XXX percent. This allows closer control where a requested
dispense is less than 1 percent. When set to "00000", this parameter
has no effect.
======================================================================

_SE (Use to lock out high settings or limit access)

_SE is the upper SETTING limits for this component. This allows a
reasonable cap to be set for each component so that an operator cannot
accidentally set the controls to an excessively high setting. For
additives, these limits will ensure that expensive material is not
wasted. Settings that are greater than the limit are held to the
limit.

EXAMPLE: If the highest color usage in your plant is 6%, then
you can enter this upper limit in the parameter table. Since

settings are stored as 1/10's of percent (##.#), the parameter
would be:
_SE 00060

Any setting above 060 is held to 6 percent.

When a 1 is entered as the first digit of this parameter,
(_SE 1xxxx), setting entries can only be made from the program mode.
In this way access is limited to only those who know the password.

======================================================================

_WT and _TI (Set AUTOMATICALLY by the CALIBRATE routine)

_WT, and _TI parameters are related to the flow rate or dispense
rate of each material. These can be changed manually, set by the RATE

Page 66

Advertising