Conair GB User Manual

Page 29

Advertising
background image

KEYPAD - DESCRIPTION OF FUNCTIONS

Three (3) operation Modes are available; AUTOMATIC, MANUAL, PROGRAM.

KEYPAD - AUTOMATIC OPERATION MODE

This is the NORMAL operating mode. When power is turned on, the unit
is in this mode. Automatic dispensing occurs ONLY in this mode. The
AUTOMATIC mode is indicated by the ABSENCE of the letter "P" or "M" at
the left end of the display.

Only the VIEW, RECIPE, BATCH, FAST, TAG, CE and EXIT keys are available
in this mode:
These keys operate only BETWEEN cycles or when the PAUSE switch is on.

To stop between cycles, use the "STOP END OF CYCLE" switch.

VIEW DATA: Press to display the CURRENT Date and Time, LAST CLEARED
(VIEW) date and time, and stored material usage data. Total
CYCLES and Material totals are available: (in Pounds, Kilos,
Grams, or Ounces)

Number of CYCLES that have occurred: (D = #####)
TOTAL weight of each component (X): (X = #####)

(only active components are displayed)
Total weight of ALL materials: (T = #####)

Each successive press of the VIEW key displays the next
total. The last displayed line will say (00=CLEAR) for 5
seconds. During this time, you may press 0,0 to clear the
data. Waiting 5 seconds or pressing any other key will exit
the sequence. When the sequence is exited, normal automatic
operation resumes. These totals may be displayed as pounds,
grams, kilograms, or ounces by a selection procedure

explained later (*89).

Press the VIEW key once followed by the "*" key to cause all
information to be sent to the printer (if available). To
then clear the data, press 00 within 5 seconds. Press any
other key or, wait 5 seconds, to continue the process
without clearing the totals.

RECIPE: This key allows you to GET, LOAD, and SAVE RECIPES. To
(RCP) SAVE a recipe you must be in the PROGRAM mode. Recipes are

thumbwheel switch settings. 50 recipes may be stored,
numbered 00 to 50.

This key is NOT FUNCTIONAL unless the third digit in the
"FLG" parameter is set to 1 (FLG xx1xx). To do this, see
the MAINTENANCE section, PARAMETER TABLE, "FLG".

Assuming a proper FLG parameter is set:
In normal Automatic mode: Press RCP key. If a RECIPE is

currently in use then display will flash through the current
stored data:
(RCP --), (1R= xx ), (2N= xx.x), etc., (CE=CLEAR)

Press CE to CLEAR CURRENT RECIPE and return settings to
those previously set. Then press RCP to look at another

Page 30

Advertising