Conair GB User Manual

Page 11

Advertising
background image

LED # 2 will light.
Press "2" repeatedly to observe operation.

REPEAT THIS SEQUENCE for each dispense valve on your WEIGH SCALE

BLENDER. Up to 12 outputs are possible numbered 1
through 9, A, B, and C. Only those connected to
devices will operate.

AT THIS POINT: NOTE which component NUMBER is assigned to each
hopper. You will want to know each hopper's
correct component number.

FACING THE CONTROLLER SIDE OF THE BLENDER:

On 9000 and 18000 gram, FOUR hopper compartment systems:
Device 1 is the NEAR hopper, 2 the FAR hopper, 3 the LEFT CENTER,
and 4 the RIGHT CENTER hopper.

On 1000, 2000, and 4000 gram, FOUR hopper systems, devices 1, 2, 3,
and 4 are counter-clockwise starting with far left corner hopper.

On 9000 and 18000 gram SIX hopper systems, devices 1, 2, 3, 4, 7, and
8 are counter-clockwise starting with far left corner hopper.

ALL MODELS:
Device 5 is the LEFT Panel-front OUTLET.
Device 6 is the RIGHT Panel-front OUTLET.

PRESS "DUMP" KEY The weigh bin air solenoid will operate.
LED # 13 will light.
The weigh bin dump valve will open.
Press "DUMP" repeatedly to observe operation.

PRESS "MIX" KEY This key controls the mix motor outlet on the
side of the controller. The mixer motor will run.
LED # 14 will light.
(Mix blade turns CCW facing the motor shaft.)
(Mixer switch must be down; timed position.)

PRESS "HOLD" KEY The Flow Control Valve will operate.
(Under the mix chamber) (This device is optional)
LED # 15 will light.

PRESS "ALARM" KEY The Strobe light and Beeper will operate.
LED # 16 will light.

PRESS "EXIT" KEY Press twice, to return to normal mode.
Verify normal mode by observing that there is NO
letter P in the display ( x).

+-----------------------------------------------------------+
¦ If you have made it this far, congratulations. ¦

¦ You have done well. ¦
¦ The load cells and controller are functioning properly. ¦
+-----------------------------------------------------------+
+----------------------------------------------------------+
¦ PROCEED TO: LOAD CELL CALIBRATION SKIP 2 PAGES ¦
+----------------------------------------------------------+

Page 12