on line, four lines of information about the dispense cycle
that just occurred will be sent to the printer. This
information includes dispense weight and percentage of each
component, the internal rate numbers used by the computer to

determine dispense time, and the actual dispense time of
each component. This is excellent information to track the
accuracy of each dispense cycle and the accuracy of the
entire system over an extended period of time.
See: PRINTER OUTPUT for a more detailed explanation.

*66 Press (*,6,6) to enter an identification number for this
particular Autoweigh Blender. This I.D. number will
appear on all printed reports. If you have more than one
unit, this helps to identify reports. If you are using a

computer to automatically gather data, then each controller
must have a unique address. Valid numbers are 000 to 255.
When connected to a computer, do not use the number 000 for
identification.

*72 This flag for SPECIAL APPLICATIONS ONLY.

Press (*,7,2) to change the Additive settings to be
interpreted as percent of the entire MIX instead of percent

of the Natural. The display will say (APM -OFF). Press "*"
to toggle flag to (APM -ON). (APM stands for Additives
Percent of Mix). This option has been added for a customer
with a unique requirement.

Leave this flag OFF, (APM- OFF), unless you have specific
instructions to do otherwise.

CAUTION: With this flag set, additive settings combined
must NOT exceed 100 percent. From a practical standpoint,

they should not exceed 10 percent combined.

*74 Press (*,7,4) to set a flag that will cause the system to
stop and the Alarm to activate when MAX weight is exceeded.
This might occur if a valve sticks open or slightly open.
Normally the system recovers automatically from such events
with only the one batch blended incorrectly. Set the flag
only if you want the system to stop and alarm.

Press * key to toggle between (MAX OK ) and (MAX ALARM).

Press EXIT when done.

*75 Press (*,7,5) to set a flag to ALARM if the weigh bin weight
drops more them 20 grams during a cycle. This serves to
detect and report a weigh bin problem, such as material
leaking from the bottom of the bin.

*77 Press (*,7,7) to print a copy of all internal parameters.
A printer must be connected and ready. Up to 13 lists will

print, a General list and 12 component lists. Only
components that are turned "on" will print. Four columns
will print, RAM; ROM; 200 and 900 series tables; and EEPROM.
Identifying headings print above each column.

*78 Press (*,7,8, followed by a 5 digit number) to change the

Page 44