set, (ROM OK ) will be displayed. To turn the flag off, you
must select this option, (*25), and, with (ROM BAD)
displayed, press the "CE" key. This will clear the flag and
it will remain off until another error is detected. The

seriousness of the problem will be somewhat indicated by the
date and time of the last bad check and how frequently you
find it necessary to turn this flag off. Even with an
error, your controller may still work perfectly. However,
we suggest you request a new program chip from us as soon as
possible.

*33 Press (*,3,3,) to turn on a special alarm condition. Press
* to toggle between (AL STD) and (AL-BATCH). If you are
running using the BATCH key, and (AL-BATCH) is selected,

then the ALARM will sound when a batch is completed.

*44 This flag for SPECIAL APPLICATIONS ONLY.

Press (*,4,4) to tell the controller to end a cycle when the
weigh bin is FULL. Use the * key to toggle between (END
EMTY) or (END FULL).

Normal operation is to end the cycle EMPTY; (END EMTY). The

(END FULL) option is only for special installations where
the sensor has been relocated BELOW the mix chamber and the
purpose of the unit is to calculate exact material usage
rates in order to control an extruder.

If you have a flow control valve fitted, this option will
increase output of the blender by allowing a cycle to start
even though the flow control valve is keeping the sensor
covered for an additional 6 seconds.

Leave this flag set to (END EMTY), unless you have specific
instructions to do otherwise.

*45 Press (*,4,5, followed by a 5 digit number) to change the
PASSWORD number for entering the MANUAL mode. The system is
supplied with the number "11111" as the password number. If
you wish to restrict use of this mode to only yourself, you
may make up your own number and enter it here.

*47 Special function, DISPENSE systems only.

This function alters the range of requested dispense
weights. 00.1 to 99.9 is standard. 001 to 999 and 0.01 to
9.99 are optional using this function. Dispense systems are
generally used for rotational molding.

*52 Press (*,5,2) to cause the weigh bin dump valve to operate
two times. We call this a "double dump". If you have
problems with material hanging up in the weigh pan, this may
help shake it loose.

Use the * key to toggle between (DBLD OFF) and (DBLD ON).
Press EXIT when done.

*54 Press (*,5,4) to set flag for a printout of data after each
full dispense cycle. With this flag ON and with a printer