Conair GB User Manual

Page 38

Advertising
background image

STAR FUNCTIONS available in this mode:

*02 This flag for EXTRUSION and YIELD control, and RATE display.

Press (*,0,2) to turn on Extrusion or Yield control.
The default display is ( OFF).
Press * to toggle this flag to ( RATE ), (EXT CTRL), or
(YLD CTRL).

If you are using our EXTRUSION or YIELD control software to
control your extruder, refer to our EXTRUSION CONTROL
instruction booklet for complete information.

If you simply want to view throughput continuously on the

blender display, set this option to ( RATE ). This will
alter the display only. In all other respects, the blender
will operate normally.

*03 Press (*,0,3) to allow four digit entry of settings in the
format (xx.xx). This does not make the blender more
accurate. It does allow easier setup for customers that
have a mixture of setting requirements, that is x.xx entry
requirements as well as the standard xx.x requirements.

Normally the XT parameter would be manually adjusted to
allow the decimal shift. If this four digit entry option is
turned on, then all entries are in the format xx.xx. The
software uses only the first three digits unless the first
digit is a zero, in which case the last three digits are
selected and the related XT parameter is set to 00010. See
XT parameter for more information. Display will say (SET=
XXX) or (SET=XXXX). Use * key to toggle.

*04 Press (*,0,4) to select from 4 standard software

configurations. If you want your unit to look and act like
it is running FOUR software, then this option will do this
for you in one easy step.

Use the "*" key to toggle through all selections.
Select ( KEYPAD ) to exit without changing anything.
Select ( R,N,C,A) for system to operate like FOUR software.
Select ( N,N,C,A) to operate like FOUR software with the
"TWO NATURALS" flag on.
Select ( N,N,N,A) to operate with three Naturals and an

additive.
Select ( R,N,N,A) to operate with Regrind, two Naturals,
and an additive.

Component 2 is ALWAYS a NATURAL, and is never assigned a
thumbwheel switch. Components 1, 3, and 4 are always
assigned to thumbwheel switches.

If ( R,N,C,A) is selected, component 2 is the ONLY natural

and is set to 100.

If ( N,N,C,A), ( N,N,N,A), or (R,N,N,A) is selected, the
first, third, and forth components are assigned to switches
3, 1, and 2 respectively. Component 2 setting will be
adjusted automatically at the start of each cycle to a

Page 39

Advertising