32

Interleaved, AdaptAtStartup, 7 db, 32 Kbps, 512 Kbps, and 8 milli-seconds.

5. Configure the line profile on RT side (Up Stream). For example,

6. Configure the line type, transmit rate adaptation, target SNR margin,

minimum transmit rate, maximum transmit rate, and interleave delay as
Interleaved, AdaptAtStartup, 7 db, 32 Kbps, 64 Kbps, and 8 milliseconds.

7. Click on the Apply button to submit your changes, or click on the Cancel

button if you want to clear all the values you have configured.

Note: (1) If you configure “Transmit Rate Adaptation” as “Fixed”, it is

recommended to configure the value of “minimum transmit rate” and
“maximum transmit rate” on CO side or RT side the same. However,
the value of CO side and RT side may not be the same.

(2) Line profile can be created maximum up to 10 profiles.

Creating a Alarm Profile {Create Alarm Profile}

This section describes how to create an ADSL alarm profile.

1. Click on “Create Alarm Profile” of DSL Profile configuration Menu.

The Create Alarm Profile screen appears as follows:

Table 3-4 Create Alarm Profile Field Definitions

Field Definition
Loss of frame within 15
minutes

The threshold of the number of “Loss of Frame
Seconds” within 15 minutes performance data
collection period.

Loss of signal within 15
minutes

The threshold of the number of “Loss of Signal
Seconds” within 15 minutes performance data
collection period.

Loss of link within 15
minutes

The threshold of the number of “Loss of Link
Seconds” within 15 minutes performance data
collection period. (But only ATU-C side)

Loss of power within

The threshold of the number of “Loss of Power

Advertising