Creating alarm profile – CTC Store CTS Union IP DSLAM for ADSL IPDSLAM-A8/A16 User Manual

Page 81

Advertising
background image

ADSL IP DSLAM


73

5. MaxTxRate:

1024

6. MaxInterleaveDelay:16

Creating Alarm Profile

This section describes how to create an alarm profile.

Command: add alarmprof <profile name>

Argument List:

Parameter type

Parameter
data-type and
field

Description

alarmprof name

String, <= 32

The name of ADSL alarm profile.

Thresh15MinLofs

Integer, 0 ~ 900

The threshold of the number of
“Loss of Frame Seconds” within
15 minutes performance data
collection period.

Thresh15MinLoss

Integer, 0 ~ 900

The threshold of the number of
“Loss of Signal Seconds” within
15 minutes performance data
collection period.

Thresh15MinLols

Integer, 0 ~ 900

The threshold of the number of
“Loss of Link Seconds” within 15
minutes performance data
collection period. (But only
ATU-C side)

Thresh15MinLprs

Integer, 0 ~ 900

The threshold of the number of
“Loss of Power Seconds” within
15 minutes performance data
collection period.

Thresh15MinESs

Integer, 0 ~ 900

The threshold of the number of
“Errored Seconds” within 15
minutes performance data
collection period.

InitFailureTrapenable enable / disable

Enable or disable the Initial
Failure Trap. Default setting is
disable. (Only on ATU-C side)

Example: This example shows how to create an alarm profile named test.

IPDSLAM # add alarmprof test
(alarmprof-atuc)# 30 10 50 5 4 enable
(alarmprof-atur)# 30 2 2 5
ADSL Alarm Profile “test” content:
ATU-C:
Thresh15MinLofs: 30
Thresh15MinLoss: 10
Thresh15MinLols: 50
Thresh15MinLprs: 5
Thresh15MinESs: 4

Advertising