96

DMX512 REFERENCE GUIDE

009

Rotating Gobo

9

Cycle from index 0 to index 1 CW, and from
index 1 to index 0 CCW repeatedly. Pause
briefly on index 0 and 1. (Test Type 9G)

8

Cycle from index 0 to index 5 CCW, and from
index 5 to index 0 CW repeatedly. Pause briefly
on index 0 and 5. (Test Type 9F)

7

Cycle from index 0 to index 3 CW, and from
index 3 to index 0 CCW repeatedly. Pause
briefly on index 0 and 3. (Test Type 9E)

6

Cycle from index 0 to index 6 CCW, and from
index 6 to index 0 CW repeatedly. Pause briefly
on index 0 and 6. (Test Type 8C)

5

Continuously index CW to next gobo position
on wheel (from 2 to 3, form 5 to 0). Gobos on
wheel do not rotate. Pause briefly on each
gobo. (Test Type 9C)

4

Cycle gobos between orientation 0 degrees &
180 degrees repeatedly. Wheel does not move.
Pause briefly at 0 and 180 degrees. (Test Type
9B)

3

Type 9A CCW, 100% speed

2

Type 9A CCW, 50% speed

1

Type 9A CCW, 25% speed

0

Spin gobos CW at 100% speed, wheel does
not move.
(Test Type 9A)

010

Strobe

9

65% speed strobe to EOT stop, (closed)

8

65% speed strobe to middle position between
EOT stops. (open)

7

25% strobe from open stop to closed stop
repeatedly (i.e. cycling)

6

35% strobe cycling

5

45% strobe cycling

4

55% strobe cycling

3

65% strobe cycling

2

75% strobe cycling

1

85% strobe cycling

0

Full speed (100%) strobe cycling

013

All Async

All tests above will run asynchronously. All
motors will reach respective EOT stops (if
applicable) and begin motion to opposite EOT
stops at each motor’s earliest opportunity.
Motion will not be coordinated between
motors.

Table 4-7: VL7/VL7U Mechanical Tests (Continued)

Test Number

Test Parameter

Error Codes/Comments