88

DMX512 REFERENCE GUIDE

Test Software/Test Tables

The following tables contain test software test numbers, parameters, error codes, and comments. Use these tables to
run luminaire tests.

Note: Test numbers not listed are not valid.

CAUTION:

Tests should not be run for more than 30 seconds, as this can further damage the luminaire. Any

tests run at FULL SPEED should not be run for more than 15 seconds.

Table 4-1: VL5 Family Mechanical Tests

Test Number

Test Parameter

Error Codes/Comments

000

Start Test

9

End Stop (Open)

001

Pan Test

8

End Stop (Clsd)

103

No Reset (Pan)

002

Tilt Test

7

Speed 1 (25%)

203

No Reset (Tilt)

004

Diffuser Test

6

Speed 2 (35%)

104

No Change (Pan)

005

Intensity Test
(VL5Arc Only)

5

Speed 3 (45%)

204

No Change (Tilt)

4

Speed 4 (55%)

006

Blue Filter Test

3

Speed 5 (65%)

007

Amber Filter Test

2

Speed 6 (75%)

008

Magenta Filter Test

1

Speed 7 (85%)

0

Speed 8 (Full Speed)

012

All Motors
(synchronized)

013

All Motors
(unsynchronized)

912

End Motor
(in calibration position)

Table 4-2: VL5 Family Default Programs

Test Number

Test

Functions

31

Pan and Tilt

701

Pan 25% Speed

702

Tilt 25% Speed

37

VL5 Functions

704

Edge 25% Speed

706

Blue Filter Test 25% Speed

707

Amber Filter Test 25% Speed

708

Magenta Filter Test 25% Speed