DMX512 REFERENCE GUIDE

73

Series 200 Luminaires

Refer also to

"DMX512 System Example"

on page 7.

Connecting to System

Series 200 luminaires will require a DMX200 interface unit in order to control them from DMX512 consoles.

Figure 3-25: Series 200 System Diagram

Step

1. Locate house AC service.

a.

Determine location of main power service where lighting system will be connected.

b.

Verify with a qualified electrician (see WARNING above) that house AC service is within system
operating voltages: 85 - 130 VAC or 170 - 260 VAC, single or three phase, 50 or 60 Hz. Ensure that
house service can accommodate connecting 2/0 pig tails or 8/5 cables to house service lugs.

Step

2. Position ACS, Mini-ACS, or SixPack chassis delta/we switches to correct setting.

Refer to

"Configuring Equipment For Delta or Wye Operation"

on page 19.

Step

3. Tie in 2/0 or 8/5 tails.

a.

Remove power from house service or verify that service disconnect switch is in the OFF position.

b.

Have a qualified electrician connect 2/0 or 8/5 pig tails to house service.

Step

4. Attach line disconnects to pig tail cable.

a.

Verify circuit breaker is in "off" position before installing line disconnect(s).

b.

Connect line disconnect(s) to end of AC tails (2/0 or 8/5). (Line disconnects should be easily accessible
in case emergency requires shutting off power to system.)

Step

5. Attach Bucking Transformer (if required).

If house AC service is below 100 VAC or above 240 VAC (Europe, Japan and Australia), it may be necessary
to connect Bucking Transformer between pig tails and lighting system ACS or modular racks to reduce or
raise voltage to desired level. (A standard Bucking Transformer accepts only Cam-Lok style connectors.)

DMX200 Translator

Y Cable

INP

U

T

ACS Rack

OUT

P

UT

INP

U

T

OUTPUT

Series 200

Lamp Cable

Data & Power

Series 200

Trunk Cable

Data & Power

Series 200 luminaires

VL2B/VL2C, VL4

DMX200 Unit

S200

Repeater

Data & Power

XLR DMX Data Cable
from DMX512 source.

Power from
Modular Rack

Advertising