Error History

The error history retains a list of the most recent 200 error codes produced since the list was cleared. When the list
becomes full, new errors overwrite the oldest errors on the list. The list can be displayed or cleared at any time. The
error history does not store test results.

To display error history, set thumbwheel switch to 40. Set test parameter to 0 to display all errors; set to any non-zero
value to display only the errors from the last test run. To control scroll speed, test thumbwheel switch to 43 and set
test parameter to select scroll speed.

To clear error history, set thumbwheel switch to 41.

To display the number of errors in the error history, set thumbwheel switch to 42. Set test parameter to 0 to display
the total number of errors. To display the number of errors recorded for the last test run, set test parameter to any
non-zero value.