DMX512 REFERENCE GUIDE

POWER AND DATA DISTRIBUTION EQUIPMENT

AC Line Disconnect (200A)

CAUTION:

Although the maximum operating limit is 200A, we recommend that continuous operating

current does not exceed 150A.

The 200A AC line disconnect is a safety device containing a three-phase,
200A circuit breaker serving as a master on/off switch for the system. The
unit connects to house service through a set of five, 10-foot, 2/0 pig tails.
The line disconnect connects to the ACS rack through a set of five, 20-
foot and/or 80-foot, 2/0 pig tail cable assemblies. One line disconnect is
required for each 200A service.

Figure 2-1: AC Line Disconnect

OUTPUT

INPUT

Neutral (White)

X Phase (Black)

Y Phase (Red)

Z Phase (Blue)

Ground (Green)

Neutral (White)

X Phase (Black)

Y Phase (Red)

Z Phase (Blue)

Ground (Green)

Bare wire to Cam-Lok Pigtail cables

Cam-Lok to Cam-Lok

from House AC service

Pigtail cables to ACS or Mod Rack