Series 300 luminaires, Connecting to system – PRG DMX Reference Guide 5.4 User Manual

Page 84

Advertising
background image

76

DMX512 REFERENCE GUIDE

Series 300 Luminaires

Refer also to

"DMX512 System Example"

on page 7.

Connecting to System

Series 300 luminaires require a Smart Repeater unit for power and control by DMX512 consoles.

Step

1. Position SixPack chassis delta/wye switches to correct setting.

Refer to

"Configuring Equipment For Delta or Wye Operation"

on page 19.

Step

2. Connect Modular Rack to power source.

Three-phase power will need to be supplied to the system. The maximum recommended mod rack power
requirement is 200 amps, using 2/0 feeder with 4/0 Cam-Lok connectors and a 200A line disconnect. A
SixPack Chassis requires 30 amps, and uses Hubbell or Epic connectors on 8/5 multicore cable. Connector
choice is dependent upon location. This cable will need to be run from a house disconnect through a 30A
line disconnect to the racks.

WARNING:

The high voltages required to run this equipment are dangerous. Electrical "tie-ins" should be

handled by a qualified electrician.

Note: Some equipment in Europe will work using single-phase power. Check with an Account Manager regarding
your event.

Figure 3-28: Series 300 Modular Rack

To House
Disconnect

Tails

Series 200 AC Line

Disconnect

Modular Rack

Feeder Cable

Advertising