Carrier

INSTALLATION

26H

FIG. 14 - CORRECT WATER LEVEL

Turn on the water and set the float valve to main­

tain a water level 3/8 " below the top of the siphon
stcujdpipe for the 26H3 and 1/2" below for the 26H5.
See Fig. 14.

The water level should be set with the pump off,
and checked again with the pump running, after the
water level has settled. To check the Siphon action
let the unit run on "Pump" until the float shuts ofi

the water to the pan. Turn the selector switch to

"Off". The water in the header and the water pipes

will drop down and raise the water pan level until
the Siphon action begins and the water pan is si­
phoned out.

If the water pan fails to siphon out, the water level
has been set too low. If the water siphons or over­
flows the inner standpipe when the pump is running,

the water level has been set too high.

After the float is set, tighten the wing nut on the
float arm and the setscrew to the flat on the float

arm. See Fig. 15.

FLOAT ASSEMBLY

17. REPLACE THE ICE DEFLECTOR

The bottom of the deflector sets in two clips fas­
tened to the inside front wall of the water pan. The

back of the ice deflector rests against the front of
the evaporator shroud. See Fig. 14.