OBSERVATION

POSSIBLE CAUSE

REMEDY AND REFERENCE

SECTIONS

Plugged capillary, either
due to moisture, dirt or

crimped capillary

Purge charge; install new strainer-
drier. If capillary is damaged, re­
place accumulator assembly

(includes capillaries )

3, 7 & 8

Cubes "hanging-up" on
ice deflector screen

Reposition deflector screen

Installation

17

Examine evaporator for warped
or bulged freezing columns

10

Bln thermostat "cut­
out " setting may be too
high

Adjust and check

30

Installation

2

Poor water distribution
due to scale on spreader
plates and/or clogged

screen on water pump

Recenter spreader plates and
water header nozzles

Clean water circuit, including
water pan and water pump screen

10, 12 & 15

15

Low refrigerant charge

Check charge and time of
freezing cycle

4

17. Irregular shaped

cubes, or mixture of
good and shell cubes.

Evaporator tubing pulled
loose from freezing columns

Replace evaporator

10

Cubes restricting one or

more columns

Examine deflector screen and ice
columns, remove obstructions

Installation

15

Raise main control "cut-in"set­
ting slightly (this will increase
defrost time)

28

Float valve set too high.
Standpipe not seated

Reset float valve; check for leaky
fl(5at valve. Seat standpipe pro­
perly.

Installation

16

Bin thermostat pre­
maturely cuts off unit

Check for a faulty bin therm­
ostat; check settings

30

Temporary power failure
during "freezing cycle"

Turn unit "off "permit ice to melt
out of columns; start unit when
power is restored

Cubes hanging up in
columns due to bulged
tubes

Check freezing columns. Replace
evaporator if columns are bulged

10