OBSERVATION

POSSIBLE CAUSE

REMEDY AND REFERENCE

SECTIONS

12. Continuous running and

Faulty main control, or

Replace if necessary

28

freezing

well capillary scaled

Check main control capillary
position in well

28

Replace if ice does not actuate
control from freezing cycle to
defrost cycle when held against
main control capillary (cut-out)

side

28

Overflow water not reach-

Scale and foreign particles may plug

15 & 28

ing overflow well and main

overflow trough tube. Check posi-

control bulb

tion of control bulb. Also check
leveling of machine

13. Unit fails to return to

Main control "cut-in " bulb

Replace main control

28

freeze cycle

has lost its charge

Low ambient temperature

Unit will not operate at ambient

Installation

temperatures below 50°

2

14. Unit continues to run

Bin control contacts fused

Replace control

30

with full bunker.

Cutout setting too low

Adjust and check

30

Ice not reaching bin

control bulb

15. Water overflowing from

Loose electrical connections

machine section

Main control, safety overflow

Check wiring and possibility of

28-29 & 30

switch or bin control failed to

stop freezing cycle

faulty controls

Leak in water pump circuit

Check water hoses and header

11 & 12

UNSATISFACTORY CUBES

16. Thin wall cubes

Manually shutting unit off

Normal as a result of such a

18

"shells ".

during a freezing cycle

shut-down. Instruct owner to
wait until end of defrost cycle
before shutting off unit

Short defrost cycle (cubes

Check main control setting; may

28

remaining in freezing

require raising cut in point

columns)

Check refrigerant charge

4

Check safety switch

27

57

26H-57PD