A C I D D I S S O L V E S T H E S C A L E

FIG. 16 - CONDENSER CLEANING PROCEDURE

CONDENSER REPLACEMENT

10. EVAPORATOR REPLACEMENT

The condenser is mounted in a vertical position

on the left side of the unit.

a. Close the water supply valve before removing

the condenser.

b. Remove front, top and left side panels.

c. Slowly bleed refrigerant from the system as

described in Section 8.

d. Unsweat all refrigerant tubing connections

while the suction valve is still open. All of
these joints are phos-copper.

e. The condenser is held by a strap screwed to

the unit frame. Lift the condenser up and out.

f. After replacing the condenser, evacuate and

recharge the system as described in Sections
4 and 8.

Bulged freezing columns may be indicated by "ex­

cessive " defrost time; 4-5 minutes before the first

ice drops and 4 minutes or longer before all the ice
drops is considered excessive defrost time.

yo determine if columns are bulged remove spreader
plates (see Fig. 17), and place light under freezing

columns and observe from the top of each column.
If several columns are seriously bulged and unit
has excessive defrost time even with adeguate

charge, the evaporator assembly should be re­

placed.

REPLACEMENT PROCEDURE

1. Remove front, top and side panels.

2. Slowly bleed refrigerant charge as described

in Section 8.