Check shipment, Storage bin crate, Heat interchanger package – Carrier 26H User Manual

Page 9: Storage bin partition, Select proper location, Move unit to location, Installation, Carrier

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Carrier

INSTALLATION

26H

-m

#

1. CHECK SHIPMENT

The unit is shipped in three cartons. One contains

the machine compartment, one the storage bin and

one the siphon interchanger assembly.

TABLE 1 - PARTS LIST

MACHINE SECTION CRATE

Model

Quantity

Description

26H3

1

Machine Section

1

Outside Standpipe

1

Water Strainer

1

Crusher Guard*

1

Inside Standpipe &
Rubber Grommet

26H5

1

Machine Section

1

Outside Standpipe

1

Water Strainer

1

Crusher Guard*

1

Inside Standpipe &
Rubber Grommet

On units equipped with crusher only.

STORAGE BIN CRATE

Size, Lb.

Quantity

Description

100, 160, 240,

1

Storage Bin

500

4

Leveling Screws

HEAT INTERCHANGER PACKAGE

Quantity

Description

1

Interchanger

1

Rubber Hose

2

Hose Clamps

STORAGE BIN PARTITION

Quantity

Description

1

Partition
Machine Screws

2. SELECT PROPER LOCATION

Select a location for the unit before delivery. The
following should be considered:

1. Convenience - Select a clean dry place as

close as possible to the point of ice consump­
tion. Consult the user before deciding.

2. Room Temperatures

Minimum 50 F - Room temperatures below this
may cause erratic control operation.

Maximum 100 F - Room temperatures above
this overload the compressor and reduce unit

capacity.

3. Floor Strength - See Table 2.

TABLE 2 - OPERATING WEIGHT AND

DIMENSIONS

Model No.

Total Weight

(Bin Full of Ice)

Bin
Cap.

Floor

Area (In.)

26H3

389

100

25

X

24

26H5

565

160

25

X

24

26H5

676

240

25

X

34

26H5

940

500

32 x50

NOTE: Add 40 lb for Crusher.

4. Clearance:

Top

Rear and Sides

Front

10" Minimum

6" Minimum

24" Minimum

5. Water Supply - See Section 12.

6. Drain Connections - See Section 12.

7. Electrical Connections - See Section 13.

3. MOVE UNIT TO LOCATION

Move the unit to the proper location before uncra­
ting. Crated dimensions are shown in Table 3.

26H-57PD