Carrier – Carrier 26H User Manual

Page 61

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Carrier

S E R V I C E

26H

26H3 WATER CONSUMPTION USING A SIPHON HEAT INTERCHANGER

Supply Water

Temp. °F.

Gallons Per Hour ***

50° Air

60° Air

70° Air

80° Air

90° Air

100° Air

50

12

12

12

12

12

12

60

15

15

15

15

15

15

70

19.2

19.2

19.2

19.2

19.2

19.2

80

27.5

27.5

27.5

27.5

27,5

27.5

90

42

42

42

42

42

42

*** Includes water for condensing, siphoning and ice-making.

(•

NOTE:

1. Figures are based on a head pressure of 125 to 130 lbs. per sq. in. gauge with 70° water and

70° air, halfway through the freezing cycle.

2. Power consumption, halfway through the freezing cycle, varies from 890 watts with 50° water

and 50° air to 980 watts with 90° water and 100° air for 26H5. Power consumption for the 26H3

under the same conditions varies from 565 to 580 watts.

61

26H-57PD