S E R V I C E
26H
#
OBSERVATION
POSSIBLE CAUSE
REMEDY AND REFERENCE
SECTIONS
4. Compressor runs- water
pump IS off.
Faulty selector switch
Repair or replace
22
Pump motor inoperative
or out on pump motor
overload
Check wiring and voltage.
Check with test cord. Repair or
replace pump and motor assembly.
17
Failure of main control to
energize pump motor con
tacts
Replace control
28
5. Water pump runs - com
pressor off.
Overload switch has opened
circuit
Check compressor overload
26
Selector switch on "pump"
Turn to "on"position
Installation
Fig. 17
Faulty selector switch
Replace selector switch
22
Compressor motor burned out Replace compressor motor
6
6. Water pump runs -
compressor hums
Loose terminals
Check and tighten
21
Compressor stuck
Replace
6
Faulty relay (opened)
Check and replace
25
Faulty starting capacitor
Check and replace
24
ERRATIC OPERATION
7. Unit will not operate
continuously - blowing
fuses.
Compressor motor faulty
Replace compressor motor
6
Low voltage
Check voltage and external
wiring
20 &
Installation
13
Faulty ice crusher motor
Repair at motor vendor service
station^ repair or replace motor.
27
8. Long Freezing Cycle
(30-40 minutes, normal).
Surrounding air temperature
high and warm supply water
temperature
Max air temp lOOF.
Max water temp 90F.
Installation
2
Faulty compressor
Repair or replace
6
Leaky solenoid valve
Turn unit on and off several times
to try to seat valve. Check wiring
for possible grounded coil.
Replace if necessary.
32
Float valve set too high
Water level should be 3/8 from
the top of the siphon standpipe on
the 26H3 and 1/2" from the top
of the siphon standpipe on the
26H5
Installation
16
Service 11
55
26H-57PD