Carrier – Carrier 26H User Manual

Page 56

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

26H

S E R V I C E

Carrier

OBSERVATION

POSSIBLE CAUSE

REMEDY AND REFERENCE

SECTIONS

8. Long Freezing Cycle

(30 - 40 min. normal)

Siphon standpipe is poorly

seated, allowing cold water
to escape

Check water pan standpipe for
proper seating

Installation

16

Float valve leaking making
siphon during freezing

period.

Check water pressure. If over 60
psig use a pressure reducing
valve and replace if necessary

Installation

12 & 16

9. Long Defrost Cycle

(Normal 5 to 8 Minutes)

Main control set incorrectly

("cut-in"temperature too
high)

Lower "cut-in"setting

28

Low-refrigerant charge

Check charge and correct if
necessary

4

Low head pressure during

the freezing cycle

Should be 125 psi. Adjust
water regulating valve

5 & 13

Bulged freezing columns

Replace evaporator,' check main

control

10

Solenoid valve stuck shut
or only partly open (listen
for hissing)

Check solenoid and wiring

32

Leaky water regulating
valve

Check and replace i f necessary

13

Water condenser scaled up

Clean condenser with inhibited
acid

9

10. During harvest cycle unit

switches back to freezing

then again to defrost

Defective interlock in main
control

Replace

28

Cut-in Bulb loose on suet,
line

Tighten clamps

28

11. Continuous running - no

ice formed.

No make up water reaching
water pan

*

Check for stuck float valve or
plugged nozzle

11

Loss of refrigerant

Check refrigerant charge; elim­
inate any leaks, add refrigerant

4

Moisture in system

Change dryer

8

Solenoid valve stuck open

Check for grounded solenoid.
Replace if necessary

32

Float setting too high
causing standpipe to
siphon

Reset float valve. Seat water pan
standpipe

Installation

16

Service 11

i

t

26H-57PD

56