Carrier – Carrier 26H User Manual

Page 50

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

26H

S E R V I C E

Carrier

INSULATED SECTION

OF BIN THERMOSTAT

CAPILLARY-

BIN

THERMOSTAT

BULB

FIG. 30 - RIGHT SIDE OF MACHINE SECTION

the bin thermostat power element from this control

and change the control mechanism without disturbing

the refrigerant system. If the thermostat bulb is
damaged, it also can be replaced separately. The
unit will not operate if the thermostat bulb has
lost its charge.

The control bulb of the bin thermostat is mounted
on a bracket near the top of the storage compart­
ment, or on the bin partition if one is used.

When the ice in the compartment comes in contact
with the bulb or capillary, the unit shuts off and
remains off until some of the ice is removed. This

control can be checked by holding two ice cubes
in contact with the bulb clamp as shown in Fig. 31.
The unit should shut off in 30 to 45 seconds. The
cut-in point should be approximately 41° for most
installations, and a differential of 7° should be
maintained.

The cut-in and cut-out temperatures may be adjusted
by turning the knurled knob on the control. When

turning this knob, the differential remains fixed.. To

THERMOSTAT

CAPILLARY

WITHIN RUBBER

HOSE INSULATION

FIG. 31 - METHOD OF CHECKING BUNKER

THERMOSTAT SETTING

adjust the differential, remove the knurled knob and

small holding plate at the top of the control, and

turn the middle adjusting screw.

C A U T I O N : The room ambient temperature must be
above 50 °F for this control to function properly.

WITHOUT PARTITION

The bin thermostat should be clamped to the back
of the bracket as shown in Fig. 32. The clomp is

attached to the bracket at the bottom hole for 240#

bins and at the top hole for 160 and 100# bins. The
thermostat capillary should run up to the top of the
bin liner along the back of the bracket to protect it

from water and ice coming from the crusher.

FIG. 32 - SKETCH SHOWING BRACKET AND

BIN (WITHOUT PARTITION).

26H-57PD

50

Advertising