Setting x.25 packet numbering modulus, Configuring the default flow control parameter – Nortel Networks 8000 User Manual

Page 220

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Nortel Secure Router 8000 Series

Configuration -WAN Access

7 LAPB and X.25 configuration

The X.25 protocol requires DTE and DCE to have the same VC range parameter;

therefore, the new configuration cannot take effect immediately after successful X.25
negotiation. It is necessary to use the

shutdown

and

undo shutdown

commands.

Setting X.25 packet numbering modulus

X.25 procedure requires DTE and DCE to have the same packet numbering mode.The

configuration takes effect when you run the

shutdown

and

undo shutdown

commands.

The packet sequence numbering mode of X.25 layer 3 is different from the frame sequence

numbering mode of LAPB (X.25 layer 2).

When you employ the modulo 128 numbering mode in the DTE or DCE interface with high

throughput rate for LAPB, you affect only the efficiency of the local DTE or DCE interface

by making an increase in point-to-point efficiency. For X.25 layer 3, you affect the end-to-end
by increasing the efficiency of communication between two sets DTEs.

Configuring the default flow control parameter

The X.25 protocol is a reliable transmission protocol with powerful flow control capability by

providing the parameters "window size" and "packet size".

Only correct configuration brings about effective and correct X.25 flow control. Any
improper configuration will result in such cases as "clearing" and "resetting". Most public

X.25 packet networks use the default window size and maximum packet size specified in the

ITU-T X.25 Recommendation, which is also true for the SR8000 making this task optional

without special requirements of service provider.

Only correct configuration brings about effective and correct X.25 flow control. Any
improper configuration results in cases such as "clearing" and "resetting". Most public X.25

packet networks, however, use the default window size and maximum packet size specified in

ITU-T X.25 Recommendation, which is also applicable for the SR8000. Therefore, this task

may be optional without special requirements of service providers.

After setting the default window size and maximum packet size:

If related parameters are not negotiated in the call process, you can establish the SVCs

with call process that use these default values. The following section describes the
parameter negotiation during call process.

If a window size or packet size option is not assigned, you can establish PVCs without

call process that use these default values. For the details about the PVC setting, refer to

the subsequent sections.

The X.25 transmitting end fragments the exceedingly long data packet of the upper layer

according to the maximum packet size, and marks the last fragment packet ( the M bit of the
last fragment packet is not set ). When the packet reaches the receiving end, X.25 reassembles
all these fragment packets, and judges whether a complete packet is received according to the

M bit marker. Therefore, a very small value of the maximum packet size consumes more

router resources, which reduces the efficiency.

Note the following points:

Maximum packet size < MTU x 8 < LAPB N1.

Due to the reasons mentioned above, new configuration does not take effect until the

shutdown

and

undo shutdown

commands are run.

Issue 5.3 (30 March 2009)

Nortel Networks Inc.

7-17

Advertising