Working under drilling unit, Opening/closing front hood, Jt9 operator’s manual – Ditch Witch JT9 User Manual

Page 128

Advertising
background image

JT9 Operator’s

Manual

Service - 127

Service Precautions

CMW

®

Working Under Drilling Unit

Before working under area of drilling unit
supported by a stabilizer, make sure drilling unit is
parked on hard surface.

1.

Remove yellow cylinder lock from storage at
rear of pipe box and place over extended
cylinder rod (shown) with curved ends toward
stabilizer shoe.

2.

Raise stabilizer to lower unit until load is
supported by cylinder lock.

Opening/Closing Front Hood

To open

1.

Unlock hood at outside latches (1).

2.

Press key lock buttons to release latches and
tip hood toward you.

3.

Release inside latch (2).

4.

Lift hood to remove.

To close

1. Align pins (3) with designated holes.

2.

Secure inside latch (2).

3.

Secure latches (1). Lock if necessary.

Crushing weight could cause death or serious injury. Use

proper procedures and equipment or stay away.

Advertising