JT9 Operator’s

Manual

Service - 135

Startup/10 Hour

CMW

®

Check Hydraulic Fluid Level

Check hydraulic fluid level before startup and every
10 hours of operation. Maintain fluid level at
halfway point on sight glass (2) when engine is off
and fluid is cool. Refill with THF at hydraulic fluid fill
(1) as necessary.

IMPORTANT: If hydraulic system must be
opened for repair, install new filter (p/n 153-791)
for first 50 hours of operation. If this filter
becomes plugged in fewer than 20 hours,
replace with clean filter. After 50 hours of normal
operation, replace with clean filter (p/n 153-792).