Antifreeze drilling unit, Add antifreeze – Ditch Witch JT2020 User Manual

Page 155

Advertising
background image

Complete the Job - 154

JT2020 Mach 1 Operator’s Manual

Antifreeze Drilling Unit

CMW

Antifreeze Drilling Unit

Your drilling unit can be left overnight in freezing conditions by circulating a polypropylene-based antifreeze
(p/n 265-644) through optional antifreeze system before shutdown.

Add Antifreeze

1.

Fill antifreeze tank with 3 gal (11 L) of approved
antifreeze.

2.

Move carriage to front of drill frame.

3.

Position 3-gal (11-L) bucket under spindle.

4.

Install plug at quick coupler for drilling fluid pump
(shown).

5.

Open valve between antifreeze tank and head of
drilling fluid pump.

6.

Turn drilling fluid potentiometer counterclockwise to
zero position.

7.

Start unit and set throttle to slow position.

8.

Slowly turn drilling fluid potentiometer clockwise
until indicator light comes on. If light does not come
on, press drilling fluid pump switch.

9.

Run drilling fluid pump until antifreeze comes out of spindle.

10. Turn drilling fluid potentiometer counterclockwise to zero position.

11. Open valve below operator’s console (shown).

12. Slowly turn drilling fluid potentiometer clockwise

until indicator light comes on.

13. Close valve below console when antifreeze runs

out of valve below console.

14. Turn drilling fluid potentiometer counterclockwise

to zero position.

Advertising